Drywall over lath and plaster walls4/14/2024 ![]() ![]() So at this point the answer seems to be no there is no plaster and lath material or wall type and one must employ some gimmick to represent or draw in the lath as part of a wall definition. Seemed odd until I read the help on how to use. If you can see the layers, it would be nice to see the base as lath.Ī re we talking wood-strip lath, as in days of yore? Yes. I'm not sure of the possible views with framing and wall construction. ![]() So it would be nice to have the proper representation. That 3/4" thickness adds up when you are trying to get the walls aligned on interior dimensions. Having balloon framing with no lath material is kind of like having a car body with no frame. I upgraded to handle balloon framing and plaster lath wall systems are an integral part of this construction method. Depending on the period of construction, they can be 36"/54" for 18" on center studs or 48" for 16"/24" on center studs. Some parts of the country, the lath is 2-3" by 1/2" thick. I would have thought there would be an editable material choice for lath along with the balloon framing since drywall was not around during the main period of this framing type. What is lath and plaster Lath is the collection of wooden slats that attach to the wall studs. The base to which you attach either plaster or drywall differs. drywall, it’s helpful to understand their key differences. Mix the finish coat with a drill and a mixing. Key Differences Between Plaster and Drywall. Apply the base coat with a thickness of about 3/8 inches. When mixing and applying the plaster, follow the manufacturer’s directions for your particular product. Apply a thin base coat of plaster to the entire wall once the bonder is dry. I have some remodeled areas that are lath and drywall, some that are just drywall and some that lath, plaster and drywall. Apply plaster bond to help the plaster bond to the drywall. The walls are roughly 3/8" lath, 1/2" scratch coat and 1/32" finish plaster. Lath in my house is typically 3/8" x 1" x 36" or 54" slats space horizontally roughly 1/2' apart. In either regard, I have a house built in 1936 that has plaster and lath on the walls and ceilings. I guess I don't understand the thrust of the clarification request. Just run your drop ceiling grid off the walls, you should be good.Represent how? Well as lath, instead of making something up to account for the thickness. Like they say "It's better to leave old dogs lie" maybe the best way of dealing with the plaster ceiling. and the landlord had the ceiling done only 4 months earlier and this house was only 76 years old. well Dad came in picked up his son walked back to the kitchen to have dinner and the ceiling in the den came crashing down and smashed the playpen. ![]() now if the keys are broken on the plaster and you have what look like big bumps remove them don't take a chance the weight of plaster is alot more then people think, I had a customer who's landlord came in and instead of fixing the plaster he had it covered up with drop ceiling, well the custmer was getting dinner ready for him and his 14 month old son, his son was in the den in the playpen. If the plaster doesn't show any pulling away from lath leave it, Don't put boards into it. Drywall and plaster two different skills two different products, the reason drywall was invented was to make wall construction faster and simpler ![]()
0 Comments
Leave a Reply.AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |